MD100 Series | BlackMAX® 4-Valve Digital Manifold

MV4 DIGITAL MANIFOLD, 1/4 & 3/8 SAE

SKU: MD100 Category:
General Details

BlackMax® Digital Manifolds are available in two and four valve models. All models feature:

Patented Modular Test & Measurement System Technology

  • US Patent No. 9,043,161

 

Best-In-Class Accuracy

  • For pressure, temperature and vacuum

 

Rugged Design

  • Water-resistant, high-strength, glass-filled nylon housing
  • Precision machined anodized aluminum manifold body
  • Proprietary Vortech® valve systems (certified to 10 microns)
  • High-impact polycarbonate LCD window
  • Advanced sight glass design

 

Simplicity & Versatility:

  • One key ON/OFF and function select
  • Supports 105 of the most common refrigerants
  • Compatible with R744 subcritical CO2 refrigerants
  • One-touch access to your 5 favorite refrigerants
  • 25 hours of continuous use with full backlight illumination

 

Full System Measurement:

  • 2 Pressures, 2 temperatures and vacuum (using MDXVG accessory)
  • Vacuum hold and pressure hold test functions

 

Simultaneously displays

  • HI and LO pressures, superheat and subcooling
  • HI and LO pressures, T1 and T2
  • HI and LO pressures, saturation T1 and saturation T2
  • HI and LO pressures, displays T1, T2 and Delta T

 

Additional wireless models include:

  • MD50
  • MD50HE
  • MD50VHE
  • MD100
  • MD100HE
  • MD100VHE
Specifications
High side pressure range  -14.5 to 800.0 PSIG (-1.0 to 55 bar)
Low side pressure range  -14.5 to 800.0 PSIG (-1.0 to 55 bar)
Pressure reading accuracy  +/- 1% of reading or +/- 0.5 PSIG (+/- 0.05 bar)
Pressure reading resolution  0.5 PSIG (0.05 bar)
High and low side burst pressure  1500.0 PSIG (103.4 bar)
High side temperature range  -58.0 °F to 302 °F (-50 °C to 150°C)
Low side temperature range  -58.0 °F to 302 °F (-50 °C to 150°C)
Temperature reading accuracy  +/- 0.36 °F (+/- 0.2°C)
Vacuum indication accuracy  +/- 10 microns (requires MDXVG accessory)
SH, SC & saturation temperature accuracy  +/- 0.5°F (+/- 0.3°C)
Instrument working temperature  -4.0 °F to 122°F (-20°C to 50°C)
Instrument working RH range  0% to 100% non-condensing
APO (Automatic Power Off)  10 minutes. Can be disabled by user.
4 valve size (L x H x W)  8.1” x 3.5” x 7.0” (20.5 cm x 8.9 cm x 17.8cm)
4 valve weight  3.3 lb. (1.5 kg)
Display Life  using 4 industrial alkaline AA batteries (included) Backlight full ON: 25+ hrs. continuous duty
Display Life  using 4 industrial alkaline AA batteries (included)  Backlight full OFF: 60+ hrs. continuous duty
Display Life using 4 Rechargeable NiMH AA batteries (not included) Backlight full ON: 20+ hrs. continuous duty from full charge
Display Life using 4 Rechargeable NiMH AA batteries (not included)  Backlight full OFF: 50+ hrs. continuous duty from full charge